European Style Vertical Exposed Fan Coil Unit
  • Air volume is from 340 to 2380 m3/h.
  • Cooling capacity is from 1.8 to 12.6 kW.
  • Used directly for large temperature difference conditions.
  • Ruidong

Availability:
Quantity:

|

 Product Description

Fan coil unit is an essential component of a central air conditioning system. It comprises a centrifugal fan and a heat exchanger made of copper tubes. The ceiling concealed fan coil unit is designed to be seamlessly integrated into the ceiling, blending with the interior decoration. Only the air outlet is visible, which not only saves space but also simplifies maintenance.

Widely application in various settings such as hotels, restaurants, factories, hospitals, exhibition halls, shopping malls, office rooms, and other industrial and civil constructions. Fan coil units are an integral part of combined air-conditioning systems that cater to cooling, heating, and other requirements.

Product Function:

1. Low noise: 

Designed to operate quietly, ensuring a comfortable and peaceful environment.

2. Easy installation: 

Easily installed, saving time and effort during the setup process.

3. Special air filter design: 

Includes a specially designed air filter that helps improve air quality by trapping dust, allergens, and other pollutants.

4. Airflow capacity: 

The unit can handle a wide range of airflows, ranging from 340 to 2380m3/h, allowing for effective air circulation in different spaces.

5. Cooling capacity: 

Cooling capacity range of 1.8 to 14kW, providing efficient cooling to meet specific cooling demands.

6. Flexible power supply: 

Work with a power supply of 220V, 50Hz, and 1 phase, accommodating different electrical systems in different countries.Can support customization.

7. Wide application:

Application in various settings including industries, hotels, commercial buildings, and more, making it suitable for a wide range of projects.

8. Cooling and heating function: 

Capable of both cooling and heating, allowing for year-round temperature control in spaces where heating is required.

|

 Product Packaging

3
Exposed type (4)
Exposed type (1)

|

 Data Sheet

Product European Style Exposed Type Fan Coil Unit
Type 2pipes 3rows
Model
22 32 52 62 72 82 102 122 142 162 202
Air Flow (m³/h) H (m³/h) 298 428 619 671 813 988 1058 1480 1560 1983 2250
M 253 364 526 570 691 840 899 1258 1326 1686 1913
L 194 278 402 436 528 642 688 962 1014 1298 1463
Cooling capacity(W) H w 1440 2060 2980 3500 4020 4500 5310 6870 7460 8610 10610
M 1180 1690 2440 2870 3300 3690 4350 5630 6120 7060 8700
L 910 1310 1890 2220 2550 2860 3370 4360 4740 5470 6740
Heating capacity(W) H w 2440 3403 5299 5763 6372 7812 9211 11290 12110 15580 17290
M 2010 2810 4370 4750 5260 6440 7600 9320 9990 12860 14270
L 1530 2130 3310 3600 3980 4880 5760 7060 7570 9740 1081
Fan Type Centrifugal double suction
Qty 1 1 2 2 2 2 2 3 3 3 4
Power Supply 220V/1P/50HZ
Input 27 32 42 55 72 80 91 125 151 161 168
Coil Rows 3 3 3 3 3 3 3 3 3 3 3
Mix.working
pressure
1.6Mpa 1.6Mpa 1.6Mpa 1.6Mpa 1.6Mpa 1.6Mpa 1.6Mpa 1.6Mpa 1.6Mpa 1.6Mpa 1.6Mpa
Pipe size Water Pipe DN20 DN20 DN20 DN20 DN20 DN20 DN20 DN20 DN20 DN20 DN20
Drain Pipe DN20 DN20 DN20 DN20 DN20 DN20 DN20 DN20 DN20 DN20 DN20
Water Flow m³/h 0.25 0.37 0.52 0.6 0.7 0.76 0.93 1.23 1.33 1.5 1.85
Water P.D. kPa 5.2 12.3 9.3 12.4 16.8 21.6 32.5 32.5 20.5 28 44.5
Noise dB(A) H 33 34 36 37 39 43 44 44 46 47 49
M 27 22 28 29 33 37 38 39 41 42 45
L 22 23 24 24 27 29 30 32 32 32 34
Net weight (kg) 18 20 22 23 25 27 29 30 34 34 37
Product European Style Exposed Type Fan Coil Unit
Type 4pipes 3+1rows
Model 22 32 52 62 72 82 102 122 142 162 202
Air Flow (m³/h) H (m³/h) 289 415 600 650 788 957 1025 1434 1512 1922 2180
M 245 353 510 553 670 814 871 1219 1285 1633 1853
L 191 274 396 429 520 632 677 947 998 1268 1439
Cooling capacity(W) H w 1380 1980 2860 3360 3860 4320 5100 6600 7160 8270 10190
M 1150 1640 2370 2790 3200 3590 4230 5470 5940 6860 8450
L 900 1290 1860 2180 2510 2810 3310 4290 4660 5370 6620
Heating capacity(W) H w 1590 2270 3290 3860 4440 4970 5860 7580 8240 9510 11710
M 1340 1910 2760 3250 3730 4170 4920 6370 6920 7980 9840
L 1030 1480 2140 2510 2880 3230 3810 4930 5350 6180 7610
Fan Type Centrifugal double suction
Qty 1 1 2 2 2 2 2 3 3 3 4
Power Supply 220V/1P/50HZ
Input 35 41 53 69 94 103 117 156 187 201 210
Coil Rows 3+1 3+1 3+1 3+1 3+1 3+1 3+1 3+1 3+1 3+1 3+1
Mix.working
pressure
1.6Mpa 1.6Mpa 1.6Mpa 1.6Mpa 1.6Mpa 1.6Mpa 1.6Mpa 1.6Mpa 1.6Mpa 1.6Mpa 1.6Mpa
Pipe size Water Pipe DN20 DN20 DN20 DN20 DN20 DN20 DN20 DN20 DN20 DN20 DN20
Drain Pipe DN20 DN20 DN20 DN20 DN20 DN20 DN20 DN20 DN20 DN20 DN20
Water Flow Cooling m³/h 0.24 0.34 0.49 0.58 0.66 0.74 0.88 1.14 1.23 1.42 1.75
Heating m³/h 0.13 0.18 0.23 0.3 0.32 0.37 0.45 0.53 0.6 0.75 0.98
Water P.D. kPa 5.2 12.3 9.3 12.4 16.8 21.6 32.5 32.5 20.5 28 44.5
Noise dB(A) H 33 34 36 37 39 43 44 44 46 47 49
M 27 22 28 29 33 37 38 39 41 42 45
L 22 23 24 24 27 29 30 32 32 32 34
Net weight (kg) 20 22 24 26 28 30 32 33 37 37 42

Note:

1. Working conditions for cooling: inlet/outlet water temperature 7°C/12°C, inlet air DB27.0 °C, WB19.5 °C.

2. Working conditions for heating: inlet/outlet water temperature 60 °C /50 °C, inlet air DB21.0 °C.

3. The noise in the table is measured by the unit in a totally anechoic room with a background noise of 16.5dB (A).

4. The static pressure at the outlet of the low static pressure unit with air outlet and filter is 0Pa: the static pressure at the outlet without air outlet and filter is 12Pa.

5. H, M and L represent high, medium and low fan speed respectively.

6. All performance parameters in the above table are measure with a power supply of 220V~/50Hz.



Previous: 
Next: 

Whatsapp:

+86-13626409993

Email us:

Call us on:

+86-15505345921
Integrating design, production, sales and installation of central air-conditioning products.

Aqua-Therm Moscow 2024
Aquatherm_logo_151
Location:Crocus Expo International Exhibition Center Moscow (Russia)
Date: 06-09 Feb., 2024'
Booth: Pavilion 3-14,C215
 
INSTALACJE Poland 2024
波兰展会
Location: ul. Głogowska 14, skr. poczt.102, 60-734 Poznań, Polska/Poland
Exhibition hall name: Poznań International Fair Ltd.
Date: April 23-25, 2024
Booth: Hall 5, No. 127
 
Bangkok RHVAC 2024
Placeholder ImageLocation: Bangkok InternationalTrade and Exhibition Center
Date: 07-10 Sep., 2024
Booth: EH103-104,BITEC
 

Useful Links

Projects

Send Us

Send Us
​Copyright 2023 Ruidong Group Co., Ltd  Sitemap. Support by:Leadong.  鲁ICP备14020406号-32