+86-15505345921      rgg@ruidonggroup.com
Home / Products / Air Handling Unit / Vertical Type Air Handling Unit / HVAC System Vertical Type Air Handling Unit
HVAC System Vertical Type Air Handling Unit
HVAC System Vertical Type Air Handling Unit HVAC System Vertical Type Air Handling Unit
HVAC System Vertical Type Air Handling Unit HVAC System Vertical Type Air Handling Unit
HVAC System Vertical Type Air Handling Unit HVAC System Vertical Type Air Handling Unit
HVAC System Vertical Type Air Handling Unit HVAC System Vertical Type Air Handling Unit
HVAC System Vertical Type Air Handling Unit HVAC System Vertical Type Air Handling Unit

loading

HVAC System Vertical Type Air Handling Unit

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button
Availability:
Quantity:

|

 Product Description

Ruidong's air handling systems possess a small size, versatile setups, attractive design, dependable performance, energy efficiency, reduced noise, effortless installation and upkeep, and more. These units find extensive applications in the central air conditioning systems of hotels,  residences, theaters, medical facilities, and sports arenas, among others.

  Characteristics of air handling units: 

1. Double-skin Panel:

    Double-skin panel use galvanized steel sheet with 30mm, 40mm or 50mm thick Polyurethane insulation between two layers.

2. Cooling coils:

    Cooling coils usually adopt copper tubes with mechanically pressed-on aluminum fins. 

    There are 4 rows, 6 rows and 8 rows coil for choice.

3. Fans and motors:

    Direct driven/ belt driven, forward curve/ backward curve centrifugal fans, and EC fan is available for option. 

    It is easy to repair and maintain, and enjoys high quality and long service life.

4. Filters:

    Flat filter G3 or G4, and bag filter are available, to meet your different requirements on cleaning class.

5. Optional devices:

    Electric heater, humidifier, eliminator, silencer, and air damper, mixing box, etc., can be add to the air handling units according to different requirements.

Our units are known for their exceptional quality, advanced techniques, energy-saving features, and ability to provide fresh and healthy air. Experience a comfortable and improved living environment with our air handling units.Please feel free to contact us if you are interested in our air conditioning.

|

 Product Details

Vertical AHU (5)
Vertical AHU (18)
Vertical AHU(31)

|

 Data Sheet

RFPL-/4H Series Return Air Condition
Model Air flow (m3/h) Rated
cooling cap.
(kW)
Rated heating cap.
(kW)
Water flow (m3/h) WaterD.P. (Kpa) ESP
(Pa)
Motor power (kW) Noise dB(A) Water pipe DN Drain pipe DN
020 2000 10.5 17.2 1.8 9.8 220 0.55 54 40 25
030 3000 15.7 25.7 2.7 13.6 220 0.75 55 40 25
040 4000 20.9 34.3 3.6 22.4 220 1.1 56 40 25
050 5000 26.2 42.9 4.5 23.6 220 1.5 58 40 25
060 6000 31.4 51.5 5.4 27.8 250 2.2 58 40 25
070 7000 36.6 60.1 6.3 32.3 250 2.2 58 50 25
080 8000 41.9 68.7 7.2 48.1 270 2.2 58 50 25
090 9000 47.1 77.2 8.1 43.5 270 2.2 59 50 25
105 10500 52.3 85.8 9.0 62.1 270 3.0 60 50 25
120 12000 62.8 103.0 10.8 48.5 270 3.0 61 50 25
135 13500 70.6 115.8 12.2 22.3 320 4.0 64 65 32
150 15000 78.5 128.7 13.5 62.5 320 4.0 66 65 32
180 18000 94.2 154.5 16.2 32.5 320 5.5 68 65 32
210 21000 109.9 180.2 18.9 37.3 350 7.5 68 65 32
240 24000 125.6 206.0 21.6 65.6 350 7.5 70 65 40
270 27000 141.3 231.7 24.3 58.2 350 7.5 71 65 40
300 30000 157.0 257.4 27.0 60.4 420 11.0 72 65 40
330 33000 172.7 283.2 29.7 75.1 420 11.0 72 80 40
350 35000 183.1 300.3 31.5 86.4 450 11.0 74 80 40
400 40000 209.3 343.3 36.0 71.4 450 11.0 75 80 40
450 45000 235.5 386.2 40.5 75.3 450 15.0 76 80 40
500 50000 261.6 429.1 45.0 81.7 450 15.0 76 80 40
Note 1.Cooling conditions:inlet air DB27℃,WB19.5℃,inlet water temperature 7℃/12℃
2.Heating conditions:inlet air DB21℃,inlet water temperature 60℃/50℃


RFPL-/6H Series Return Air Condition
Model Air flow (m3/h) Rated
cooling cap.
(kW)
Rated heating cap.
(kW)
Water flow (m3/h) WaterD.P. (Kpa) ESP
(Pa)
Motor power (kW) Noise dB(A) Water pipe DN Drain pipe DN
020 2000 15.1 24.8 2.60 22 220 0.55 54 40 25
030 3000 22.7 37.2 3.90 35 220 1.1 55 40 25
040 4000 30.2 49.6 5.20 46 220 1.1 56 40 25
050 5000 37.8 62.0 6.50 43 220 1.5 58 40 25
060 6000 45.3 74.4 7.80 54 250 2.2 58 40 25
070 7000 52.9 86.8 9.10 24 250 2.2 58 50 25
080 8000 60.5 99.2 10.40 35 270 2.2 58 50 25
090 9000 68.0 111.6 11.70 38 270 3.0 59 50 25
105 10500 79.4 130.2 13.65 43 270 3.0 60 50 25
120 12000 90.7 148.7 15.60 46 270 3.0 61 50 25
135 13500 102.0 167.3 17.55 48 320 4.0 64 65 32
150 15000 113.4 185.9 19.50 51 320 5.5 66 65 32
180 18000 136.0 223.1 23.40 23 320 5.5 68 65 32
210 21000 158.7 260.3 27.30 26 350 7.5 68 65 32
240 24000 181.4 297.5 31.20 35 350 7.5 70 65 40
270 27000 204.1 334.7 35.10 42 350 11.0 71 65 40
300 30000 226.7 371.9 39.0 44 420 11.0 72 65 40
330 33000 249.4 409.0 42.90 53 420 11.0 72 80 40
350 35000 264.5 433.8 45.50 63 450 11.0 74 80 40
400 40000 302.3 495.8 52.0 54 450 15.0 75 80 40
450 45000 340.1 557.8 58.50 61 450 15.0 76 80 40
500 50000 377.9 619.8 65.0 67 450 18.5 76 80 40
Note 1.Cooling conditions:inlet air DB27℃,WB19.5℃,inlet water temperature 7℃/12℃
2.Heating conditions:inlet air DB21℃,inlet water temperature 60℃/50℃