Number of pipes:4rows
Model:FP34 - FP238
Air flow:340m³/h-2380m³/h
Installation method:Left type/Right type
External static pressure :12pa/30pa/50pa
  • Horizontal Concealed Water Fan Coil Unit

  • Ruidong Group

Availability:
Quantity:

|

 Product Description

A fan coil unit (FCU) is a device that is mounted on the ceiling and consists of a fan and a coil for heating or cooling. It is an integral component of HVAC systems and can be found in various types of buildings, including residential, commercial, and industrial.

 Fan coil unit (FCU) will generally consist of the following components:

  • Cased or Uncased [casing around unit]

  • Air Intake

  • Filter

  • Fan

  • Cooling Coil [water/dx]

  • Heating Coil [water/electric]

  • Discharge

  • Grille [intake/discharge]

  • Speed controller/on/off switch

  • Duct/Wall mounted thermostat

  • Modulating/on/off valve


 Fan Coil Unit Schematic Diagram [Typical 2 pipe] 

The diagram below depicts a standard pipework configuration for a two-pipe fan coil unit, accompanied by an explanation of the two-pipe system.

两管制

The two-pipe system is the fundamental and simplest form of design and installation for a fan coil unit, and it offers three possible configurations.

  1. Cooling Only

  2. Heating Only

  3. Cooling or Heating

    Cooling Only     

A cooling-only unit will only be supplied by chilled water to the coil, and these are usually found installed in spaces where no heating is required throughout the year.

Usually found in hotter climates and small computer/server rooms.

     Heating Only   

Similar to the cooling-only system, the unit will be only supplied by hot water to the coil, and these are usually found installed in spaces where no cooling is required throughout the year.

Usually found in colder climates.

     Cooling or Heating   

The cooling or heating option is entirely dependent on the time of year, in the summer, the central chilled water system will feed the 2 pipe systems and coil, whilst in the winter, it will switch over and be fed by the central heating system.


  Fan Coil Unit Schematic Diagram [Typical 4 pipe]  

Below is a typical pipework configuration for a four [4] pipe fan coil unit, along with a description provided underneath.

四管制

The four [4] pipe system employs two [2] coils within the FCU, one for cooling and one for heating. This configuration offers significant advantages as it eliminates the need for seasonal changeovers and allows for automatic temperature management within the space.

The FCU is connected to both the central heating and central chilled water systems concurrently. Control valves within each system regulate the supply of appropriate temperatures to the FCU.

If you encounter any problems during the product selection process, please feel free to contact us. The following are the specific parameters of the product.

|

 Product Details

2 (32)
2 (65)
photobank (1)

 

|

 Data Sheet

Product Ceiling Concealed Type Fan Coil Unit
Type 4pipes 3+1 rows
Model RFP-34 RFP-51 RFP-68 RFP-85 RFP-102 RFP-136 RFP-170 RFP-204 RFP-238
Air Flow (m³/h) H 340 510 680 850 1020 1360 1700 2040 2380
M 265 405 535 680 790 1060 1360 1595 1904
L 195 305 405 510 585 790 1020 1180 1428
Cooling capacity (W) H 1890 2830 3780 4680 5610 7350 9000 10800 12600
Heating capacity (W) H 1480 2220 2960 3720 4150 5180 6700 7290 8500
Input Power (W) 12Pa 37 52 62 76 96 134 152 189 228
30Pa 44 59 72 87 108 156 174 212 253
50Pa 49 66 84 100 118 174 210 250 300
Noise dB (A) 12Pa 37 39 41 43 46 46 48 50 52
30Pa 40 42 44 46 47 48 50 52 54
50Pa 42 44 46 47 49 50 52 54 56
Water Flow Coolibg 0.33 0.5 0.67 0.8 0.96 1.26 1.55 1.86 2.18
Heating 0.13 0.19 0.25 0.32 0.37 0.45 0.58 0.63 0.73
Water P.D. kPa 30 30 30 30 40 40 40 40 50
Fan Type Forward multi-wing centrifugal double suction fan
Motor Type Capacitor running asynchronous motor
Coil Rows 3+1
Pressure Design pressure 1.6MPa,test pressure 2.5MPa
Pipe size Water Pipe R3/4(internal thread)
Drain Pipe R3/4(internal thread)
Net weight (kg) 15.4 17.2 19.1 20.5 22 29.7 31.5 35.6 41.5
Optional accessories Thermostat,2-way/3-way valve,return box



Previous: 
Next: 

Whatsapp:

+86-13626409993

Email us:

Call us on:

+86-15505345921
Integrating design, production, sales and installation of central air-conditioning products.

Bangkok RHVAC 2024
Placeholder ImageLocation: Bangkok InternationalTrade and Exhibition Center
Date: 07-10 Sep., 2024
Booth: EH103-104,BITEC
 

Useful Links

Projects

Send Us

Send Us
​Copyright 2023 Ruidong Group Co., Ltd  Sitemap. Support by:Leadong.  鲁ICP备14020406号-32