Ruidong
Availability: | |
---|---|
Quantity: | |
|
Product Description
Fan coil unit is an essential component of a central air conditioning system. It comprises a centrifugal fan and a heat exchanger made of copper tubes. The ceiling concealed fan coil unit is designed to be seamlessly integrated into the ceiling, blending with the interior decoration. Only the air outlet is visible, which not only saves space but also simplifies maintenance.
Widely application in various settings such as hotels, restaurants, factories, hospitals, exhibition halls, shopping malls, office rooms, and other industrial and civil constructions. Fan coil units are an integral part of combined air-conditioning systems that cater to cooling, heating, and other requirements.
Product Function:
1. Low noise:
Designed to operate quietly, ensuring a comfortable and peaceful environment.
2. Easy installation:
Easily installed, saving time and effort during the setup process.
3. Special air filter design:
Includes a specially designed air filter that helps improve air quality by trapping dust, allergens, and other pollutants.
4. Airflow capacity:
The unit can handle a wide range of airflows, ranging from 340 to 2380m3/h, allowing for effective air circulation in different spaces.
5. Cooling capacity:
Cooling capacity range of 1.8 to 14kW, providing efficient cooling to meet specific cooling demands.
6. Flexible power supply:
Work with a power supply of 220V, 50Hz, and 1 phase, accommodating different electrical systems in different countries.Can support customization.
7. Wide application:
Application in various settings including industries, hotels, commercial buildings, and more, making it suitable for a wide range of projects.
8. Cooling and heating function:
Capable of both cooling and heating, allowing for year-round temperature control in spaces where heating is required.
|
Product Packaging
|
Data Sheet
Product | European Style Exposed Type Fan Coil Unit | ||||||||||||
Type | 2pipes 3rows | ||||||||||||
Model | 22 | 32 | 52 | 62 | 72 | 82 | 102 | 122 | 142 | 162 | 202 | ||
Air Flow (m³/h) | H | (m³/h) | 298 | 428 | 619 | 671 | 813 | 988 | 1058 | 1480 | 1560 | 1983 | 2250 |
M | 253 | 364 | 526 | 570 | 691 | 840 | 899 | 1258 | 1326 | 1686 | 1913 | ||
L | 194 | 278 | 402 | 436 | 528 | 642 | 688 | 962 | 1014 | 1298 | 1463 | ||
Cooling capacity(W) | H | w | 1440 | 2060 | 2980 | 3500 | 4020 | 4500 | 5310 | 6870 | 7460 | 8610 | 10610 |
M | 1180 | 1690 | 2440 | 2870 | 3300 | 3690 | 4350 | 5630 | 6120 | 7060 | 8700 | ||
L | 910 | 1310 | 1890 | 2220 | 2550 | 2860 | 3370 | 4360 | 4740 | 5470 | 6740 | ||
Heating capacity(W) | H | w | 2440 | 3403 | 5299 | 5763 | 6372 | 7812 | 9211 | 11290 | 12110 | 15580 | 17290 |
M | 2010 | 2810 | 4370 | 4750 | 5260 | 6440 | 7600 | 9320 | 9990 | 12860 | 14270 | ||
L | 1530 | 2130 | 3310 | 3600 | 3980 | 4880 | 5760 | 7060 | 7570 | 9740 | 1081 | ||
Fan | Type | Centrifugal double suction | |||||||||||
Qty | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 4 | ||
Power | Supply | 220V/1P/50HZ | |||||||||||
Input | 27 | 32 | 42 | 55 | 72 | 80 | 91 | 125 | 151 | 161 | 168 | ||
Coil | Rows | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
Mix.working pressure | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | ||
Pipe size | Water Pipe | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | |
Drain Pipe | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | ||
Water Flow | m³/h | 0.25 | 0.37 | 0.52 | 0.6 | 0.7 | 0.76 | 0.93 | 1.23 | 1.33 | 1.5 | 1.85 | |
Water P.D. | kPa | 5.2 | 12.3 | 9.3 | 12.4 | 16.8 | 21.6 | 32.5 | 32.5 | 20.5 | 28 | 44.5 | |
Noise dB(A) | H | 33 | 34 | 36 | 37 | 39 | 43 | 44 | 44 | 46 | 47 | 49 | |
M | 27 | 22 | 28 | 29 | 33 | 37 | 38 | 39 | 41 | 42 | 45 | ||
L | 22 | 23 | 24 | 24 | 27 | 29 | 30 | 32 | 32 | 32 | 34 | ||
Net weight | (kg) | 18 | 20 | 22 | 23 | 25 | 27 | 29 | 30 | 34 | 34 | 37 |
Product | European Style Exposed Type Fan Coil Unit | ||||||||||||
Type | 4pipes 3+1rows | ||||||||||||
Model | 22 | 32 | 52 | 62 | 72 | 82 | 102 | 122 | 142 | 162 | 202 | ||
Air Flow (m³/h) | H | (m³/h) | 289 | 415 | 600 | 650 | 788 | 957 | 1025 | 1434 | 1512 | 1922 | 2180 |
M | 245 | 353 | 510 | 553 | 670 | 814 | 871 | 1219 | 1285 | 1633 | 1853 | ||
L | 191 | 274 | 396 | 429 | 520 | 632 | 677 | 947 | 998 | 1268 | 1439 | ||
Cooling capacity(W) | H | w | 1380 | 1980 | 2860 | 3360 | 3860 | 4320 | 5100 | 6600 | 7160 | 8270 | 10190 |
M | 1150 | 1640 | 2370 | 2790 | 3200 | 3590 | 4230 | 5470 | 5940 | 6860 | 8450 | ||
L | 900 | 1290 | 1860 | 2180 | 2510 | 2810 | 3310 | 4290 | 4660 | 5370 | 6620 | ||
Heating capacity(W) | H | w | 1590 | 2270 | 3290 | 3860 | 4440 | 4970 | 5860 | 7580 | 8240 | 9510 | 11710 |
M | 1340 | 1910 | 2760 | 3250 | 3730 | 4170 | 4920 | 6370 | 6920 | 7980 | 9840 | ||
L | 1030 | 1480 | 2140 | 2510 | 2880 | 3230 | 3810 | 4930 | 5350 | 6180 | 7610 | ||
Fan | Type | Centrifugal double suction | |||||||||||
Qty | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 4 | ||
Power | Supply | 220V/1P/50HZ | |||||||||||
Input | 35 | 41 | 53 | 69 | 94 | 103 | 117 | 156 | 187 | 201 | 210 | ||
Coil | Rows | 3+1 | 3+1 | 3+1 | 3+1 | 3+1 | 3+1 | 3+1 | 3+1 | 3+1 | 3+1 | 3+1 | |
Mix.working pressure | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | ||
Pipe size | Water Pipe | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | |
Drain Pipe | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | ||
Water Flow | Cooling | m³/h | 0.24 | 0.34 | 0.49 | 0.58 | 0.66 | 0.74 | 0.88 | 1.14 | 1.23 | 1.42 | 1.75 |
Heating | m³/h | 0.13 | 0.18 | 0.23 | 0.3 | 0.32 | 0.37 | 0.45 | 0.53 | 0.6 | 0.75 | 0.98 | |
Water P.D. | kPa | 5.2 | 12.3 | 9.3 | 12.4 | 16.8 | 21.6 | 32.5 | 32.5 | 20.5 | 28 | 44.5 | |
Noise dB(A) | H | 33 | 34 | 36 | 37 | 39 | 43 | 44 | 44 | 46 | 47 | 49 | |
M | 27 | 22 | 28 | 29 | 33 | 37 | 38 | 39 | 41 | 42 | 45 | ||
L | 22 | 23 | 24 | 24 | 27 | 29 | 30 | 32 | 32 | 32 | 34 | ||
Net weight | (kg) | 20 | 22 | 24 | 26 | 28 | 30 | 32 | 33 | 37 | 37 | 42 |
Note:
1. Working conditions for cooling: inlet/outlet water temperature 7°C/12°C, inlet air DB27.0 °C, WB19.5 °C.
2. Working conditions for heating: inlet/outlet water temperature 60 °C /50 °C, inlet air DB21.0 °C.
3. The noise in the table is measured by the unit in a totally anechoic room with a background noise of 16.5dB (A).
4. The static pressure at the outlet of the low static pressure unit with air outlet and filter is 0Pa: the static pressure at the outlet without air outlet and filter is 12Pa.
5. H, M and L represent high, medium and low fan speed respectively.
6. All performance parameters in the above table are measure with a power supply of 220V~/50Hz.
|
Product Description
Fan coil unit is an essential component of a central air conditioning system. It comprises a centrifugal fan and a heat exchanger made of copper tubes. The ceiling concealed fan coil unit is designed to be seamlessly integrated into the ceiling, blending with the interior decoration. Only the air outlet is visible, which not only saves space but also simplifies maintenance.
Widely application in various settings such as hotels, restaurants, factories, hospitals, exhibition halls, shopping malls, office rooms, and other industrial and civil constructions. Fan coil units are an integral part of combined air-conditioning systems that cater to cooling, heating, and other requirements.
Product Function:
1. Low noise:
Designed to operate quietly, ensuring a comfortable and peaceful environment.
2. Easy installation:
Easily installed, saving time and effort during the setup process.
3. Special air filter design:
Includes a specially designed air filter that helps improve air quality by trapping dust, allergens, and other pollutants.
4. Airflow capacity:
The unit can handle a wide range of airflows, ranging from 340 to 2380m3/h, allowing for effective air circulation in different spaces.
5. Cooling capacity:
Cooling capacity range of 1.8 to 14kW, providing efficient cooling to meet specific cooling demands.
6. Flexible power supply:
Work with a power supply of 220V, 50Hz, and 1 phase, accommodating different electrical systems in different countries.Can support customization.
7. Wide application:
Application in various settings including industries, hotels, commercial buildings, and more, making it suitable for a wide range of projects.
8. Cooling and heating function:
Capable of both cooling and heating, allowing for year-round temperature control in spaces where heating is required.
|
Product Packaging
|
Data Sheet
Product | European Style Exposed Type Fan Coil Unit | ||||||||||||
Type | 2pipes 3rows | ||||||||||||
Model | 22 | 32 | 52 | 62 | 72 | 82 | 102 | 122 | 142 | 162 | 202 | ||
Air Flow (m³/h) | H | (m³/h) | 298 | 428 | 619 | 671 | 813 | 988 | 1058 | 1480 | 1560 | 1983 | 2250 |
M | 253 | 364 | 526 | 570 | 691 | 840 | 899 | 1258 | 1326 | 1686 | 1913 | ||
L | 194 | 278 | 402 | 436 | 528 | 642 | 688 | 962 | 1014 | 1298 | 1463 | ||
Cooling capacity(W) | H | w | 1440 | 2060 | 2980 | 3500 | 4020 | 4500 | 5310 | 6870 | 7460 | 8610 | 10610 |
M | 1180 | 1690 | 2440 | 2870 | 3300 | 3690 | 4350 | 5630 | 6120 | 7060 | 8700 | ||
L | 910 | 1310 | 1890 | 2220 | 2550 | 2860 | 3370 | 4360 | 4740 | 5470 | 6740 | ||
Heating capacity(W) | H | w | 2440 | 3403 | 5299 | 5763 | 6372 | 7812 | 9211 | 11290 | 12110 | 15580 | 17290 |
M | 2010 | 2810 | 4370 | 4750 | 5260 | 6440 | 7600 | 9320 | 9990 | 12860 | 14270 | ||
L | 1530 | 2130 | 3310 | 3600 | 3980 | 4880 | 5760 | 7060 | 7570 | 9740 | 1081 | ||
Fan | Type | Centrifugal double suction | |||||||||||
Qty | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 4 | ||
Power | Supply | 220V/1P/50HZ | |||||||||||
Input | 27 | 32 | 42 | 55 | 72 | 80 | 91 | 125 | 151 | 161 | 168 | ||
Coil | Rows | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
Mix.working pressure | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | ||
Pipe size | Water Pipe | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | |
Drain Pipe | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | ||
Water Flow | m³/h | 0.25 | 0.37 | 0.52 | 0.6 | 0.7 | 0.76 | 0.93 | 1.23 | 1.33 | 1.5 | 1.85 | |
Water P.D. | kPa | 5.2 | 12.3 | 9.3 | 12.4 | 16.8 | 21.6 | 32.5 | 32.5 | 20.5 | 28 | 44.5 | |
Noise dB(A) | H | 33 | 34 | 36 | 37 | 39 | 43 | 44 | 44 | 46 | 47 | 49 | |
M | 27 | 22 | 28 | 29 | 33 | 37 | 38 | 39 | 41 | 42 | 45 | ||
L | 22 | 23 | 24 | 24 | 27 | 29 | 30 | 32 | 32 | 32 | 34 | ||
Net weight | (kg) | 18 | 20 | 22 | 23 | 25 | 27 | 29 | 30 | 34 | 34 | 37 |
Product | European Style Exposed Type Fan Coil Unit | ||||||||||||
Type | 4pipes 3+1rows | ||||||||||||
Model | 22 | 32 | 52 | 62 | 72 | 82 | 102 | 122 | 142 | 162 | 202 | ||
Air Flow (m³/h) | H | (m³/h) | 289 | 415 | 600 | 650 | 788 | 957 | 1025 | 1434 | 1512 | 1922 | 2180 |
M | 245 | 353 | 510 | 553 | 670 | 814 | 871 | 1219 | 1285 | 1633 | 1853 | ||
L | 191 | 274 | 396 | 429 | 520 | 632 | 677 | 947 | 998 | 1268 | 1439 | ||
Cooling capacity(W) | H | w | 1380 | 1980 | 2860 | 3360 | 3860 | 4320 | 5100 | 6600 | 7160 | 8270 | 10190 |
M | 1150 | 1640 | 2370 | 2790 | 3200 | 3590 | 4230 | 5470 | 5940 | 6860 | 8450 | ||
L | 900 | 1290 | 1860 | 2180 | 2510 | 2810 | 3310 | 4290 | 4660 | 5370 | 6620 | ||
Heating capacity(W) | H | w | 1590 | 2270 | 3290 | 3860 | 4440 | 4970 | 5860 | 7580 | 8240 | 9510 | 11710 |
M | 1340 | 1910 | 2760 | 3250 | 3730 | 4170 | 4920 | 6370 | 6920 | 7980 | 9840 | ||
L | 1030 | 1480 | 2140 | 2510 | 2880 | 3230 | 3810 | 4930 | 5350 | 6180 | 7610 | ||
Fan | Type | Centrifugal double suction | |||||||||||
Qty | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 4 | ||
Power | Supply | 220V/1P/50HZ | |||||||||||
Input | 35 | 41 | 53 | 69 | 94 | 103 | 117 | 156 | 187 | 201 | 210 | ||
Coil | Rows | 3+1 | 3+1 | 3+1 | 3+1 | 3+1 | 3+1 | 3+1 | 3+1 | 3+1 | 3+1 | 3+1 | |
Mix.working pressure | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | 1.6Mpa | ||
Pipe size | Water Pipe | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | |
Drain Pipe | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | ||
Water Flow | Cooling | m³/h | 0.24 | 0.34 | 0.49 | 0.58 | 0.66 | 0.74 | 0.88 | 1.14 | 1.23 | 1.42 | 1.75 |
Heating | m³/h | 0.13 | 0.18 | 0.23 | 0.3 | 0.32 | 0.37 | 0.45 | 0.53 | 0.6 | 0.75 | 0.98 | |
Water P.D. | kPa | 5.2 | 12.3 | 9.3 | 12.4 | 16.8 | 21.6 | 32.5 | 32.5 | 20.5 | 28 | 44.5 | |
Noise dB(A) | H | 33 | 34 | 36 | 37 | 39 | 43 | 44 | 44 | 46 | 47 | 49 | |
M | 27 | 22 | 28 | 29 | 33 | 37 | 38 | 39 | 41 | 42 | 45 | ||
L | 22 | 23 | 24 | 24 | 27 | 29 | 30 | 32 | 32 | 32 | 34 | ||
Net weight | (kg) | 20 | 22 | 24 | 26 | 28 | 30 | 32 | 33 | 37 | 37 | 42 |
Note:
1. Working conditions for cooling: inlet/outlet water temperature 7°C/12°C, inlet air DB27.0 °C, WB19.5 °C.
2. Working conditions for heating: inlet/outlet water temperature 60 °C /50 °C, inlet air DB21.0 °C.
3. The noise in the table is measured by the unit in a totally anechoic room with a background noise of 16.5dB (A).
4. The static pressure at the outlet of the low static pressure unit with air outlet and filter is 0Pa: the static pressure at the outlet without air outlet and filter is 12Pa.
5. H, M and L represent high, medium and low fan speed respectively.
6. All performance parameters in the above table are measure with a power supply of 220V~/50Hz.